Viking F21168 Refrigerator User Manual


 
Operation
16
Operation
Standard No. 42: Aesthetic Effects
Parameter
USEPA
MCL
Influent
Challenge
Concentration
Influent
Average
Effluent
% Reduction
Min.
Required
Reduction
Avg. Max.
Avg. Min.
Chlorine
2.0 mg/L
+ 10%
1.88 mg/L
<0.051363
mg/L
0.06
mg/L
>97.26%
96.84%
50%
T & O
Particulate**
at least 10,000
particles/ml
57,000,000
#/ml
30,583
#/ml
69,000
#/ml
99.52% 98.94% 85%
Water Filter
Standard No. 53: Health Effects
Parameter
USEPA
MCL
Influent
Challenge
Concentration
Influent
Average
Effluent
% Reduction
Min.
Required
Reduction
Avg. Max.
Avg. Min.
Turbidity 1NTU** 11 + 1 NTU*** 10.7 NTU .031 NTU 0.49 NTU 97.09% 95.20% 0.5NTU
Cysts
99.5%
Red
Minimum
50,000/L
166,500
#/L
L <1 #/L <1 #/L >99.99% >99.99% >99.95%
Asbestos
99%
Red
107 108 fibers/
L; fibers >10
micrometers in
length
155 MF/L <1 MF/L <1 MF/L >99.99% >99.99% 99%
Lead at
pH 6.5
0.015
mg/L
0.15 mg/L
+ 10%
0.153
mg/L
<0.001
mg/L
<0.001
mg/L
>99.35% >99.29% 0.10 mg/L
Lead at
pH 8.5
0.015
mg/L
0.15 mg/L
+ 10%
0.150
mg/L
<0.001
mg/L
<0.001
mg/L
>99.33% >99.29% 0.10 mg/L
Mercury at
pH 6.5
0.002
mg/L
0.06 mg/L
+ 10%
0.006
mg/L
<0.003
mg/L
<0.005
mg/L
95.70% 90.91%
0.002
mg/L
Mercury at
pH 8.5
0.002
mg/L
0.06 mg/L
+ 10%
0.006
mg/L
<0.008
mg/L
<0.015
mg/L
86.22% 75.93%
0.002
mg/L
Atrazine
0.003
mg/L
0.09 mg/L
+ 10%
0.009
mg/L
<0.002
mg/L
<0.002
mg/L
76.99% 75.31%
0.003
mg/L
Benzene
0.005
mg/L
0.15 mg/L
+ 10%
0.014
mg/L
<0.006
mg/L
<0.011
mg/L
95.71% 92.14%
0.005
mg/L
Carbofuran
0.04
mg/L
0.08 mg/L
+ 10%
0.081
mg/L
<0.001
mg/L
<0.001
mg/L
98.74% 98.46% 0.04 mg/L
p-Dichlorob-
enzene
0.075
mg/L
0.225 mg/L
+ 10%
0.208
mg/L
<0.005
mg/L
<0.005
mg/L
99.76% 99.74%
0.075
mg/L
Lindane
0.0002
mg/L
0.002 mg/L
+ 10%
0.002
mg/L
<0.000
mg/L
<0.001
mg/L
98.72% 96.50%
0.0002
mg/L
Toxaphene
0.003
mg/L
0.15 mg/L
+ 10%
0.015
mg/L
<0.001
mg/L
<0.001
mg/L
92.97% 91.67%
0.003
mg/L
*Tested using a flow rate of 0.78 gpm; pressure of 60psig; pH of 7.5 + 0.5; temp of
68˚ + 5˚F (20˚ + 3˚C).
**Measurement in Particles/ml. Particles used were 0.5 - 1 microns
***NTU - Nephelometric Turbidity Units
Water Filter Certifications
State of California
Department of Public Health
Water Treatment Device
Certificate Number
Date Issued: June 1, 2011
Trademark/Model Designation
Replacement Elements
179006
-
Viking, RWFFR-750
RWFF
R
Manufacturer:
3M Purification Inc.
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Cysts
Turbidity
Asbestos
Lead
Mercury
Atrazine
Benzene
Carbofuran
Lindane
p-Dichlorobenzene
Toxaphene
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Organic Contaminants
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified
for cyst reduction may be used on disinfected waters that may contain filterable cysts.
750 gals
Rated Service Capacity:
0.78 gpm
Rated Service Flow:
Conditions of Certification: