8
CLEANING INSTRUCTIONS
PERMANENT AGITATOR:
1. Fill a durable square or rectangular container to within 1” of the top with hot (110˚F)
water containing Ivory liquid detergent (1 oz. per qt.). The container must be deep
enough to submerge the entire agitator and the shaft.
2. Hold the container up around the agitator and shaft, all the way up to the bottom
of the motor chamber, and turn the mixer on. Run for about 15 seconds. Repeat
several times. Make sure all portions of the shaft whichever contact food have been
submerged. (Sliding splash guard cups must be removed for this cleaning opera-
tion).
3. Repeat step 2, except use 105˚F rinse water.
4. Repeat step 2, except use 100ppm solution of Stera-R-Sheen Green label and run
agitator and shaft under solution for a minimum of two minutes total. To mix solu-
tion use one heaping tablespoon (1 ounce) of Stera-R-Sheen Green Label per gallon
of warm water (105˚F).
5. Resanitize at the start of the day per above instructions.
ALL MODELS:
6. Unplug the mixer.
7. Wall Mount Units only: Remove the sliding splash guard cup (*) and wash in a
detergent solution and sanitize. Do not use any abrasive material or paper towels
which would scratch the surface. Also avoid cleaners which contain ammonia (most
window cleaners contain ammonia). Not recommended for dishwashers.
*(To remove the moving sliding splash guard cup, squeeze the travel rods together and
slide the guard down. To mount the sliding splash guard cup slide the sliding splash
guard cup up over the rods till they snap in place. Resanitize at the start of the day.)
8. Cleaning the travel rods: To clean the travel rods just wipe them off. DO NOT
remove the rods from the mixer.
9. All stainless steel surfaces may be cleaned and disinfected with any commercial
cleaning solutions. However, do not spray any water or other uids into the motor
chamber. Do not use excess liquid around the switch, motor protector, or cord entry
hole. Abrasive may leave noticeable changes in the surface nish. Make sure all areas
in and around the motor enclosure are dry before plugging the mixer back in.
10. The foot control should be kept dry. Do not leave it on the oor when mopping or
washing the oor. When cleaning is required, unplug and clean with damp rag. Wait
until thoroughly dry before plugging back in.
Note: Never try to wipe the shaft when running. The rag can be ripped from your
hand resulting in severe unbalance with possible personal injury or damage to the
equipment.
The spoon agitator is disposable and should be discarded after one use.
PRESSURE SWITCH
BREAKER
CORD 120V INPUT
Brown
Lt. Blue
Yellow w/Green
Blue
Blue
Blue
Blue
Blue
Brown
Red
Brown
Yellow
Green
w/Y
ellow
M
O
T
O
R
ON/OFF SWITCH
M21
(2)
M2
M9
M10
M8