Vulcan-Hart 1GR65C Fryer User Manual


 
GRDF / GRCF SERIES GAS FRYERS
VULCAN-HART F-31214 Rev. D (March 2008)
-6-
Clearances
Minimum clearance from combustible construction:
6” (15 cm) from the sides of the fryer
6” (15 cm) from the back of the fryer
The fryer may be installed on combustible floors
Minimum clearance from noncombustible construction:
0” from the sides of the fryer
0” from the back of the fryer
Between the fryer and any open-top flame units:
16” (41 cm)
Allow space for servicing and operation.
Location
Install fryer in an area with sufficient air supply for gas combustion at fryer
burners.
Do not obstruct the flow of combustion and ventilation air.
Provide adequate clearance for air openings into the combustion chamber.
Do not permit fans to blow directly onto fryer.
Avoid wall-type fans, which create cross-currents within a room. Avoid
open windows next to sides or back.
CODES AND STANDARDS
The fryer must be installed in accordance with:
In the United States:
State and local codes, or in the absence of local codes, with:
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may
be obtained from The American Gas Association Accredited Standards
Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the
Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-
7471.
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition,
available from the National Fire Protection Association, Batterymarch Park,
Quincy, MA. 02169-7471.
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained
from The National Fire Protection Association, Batterymarch Park, Quincy,
MA. 02169-7471.