Vulcan-Hart 24RRG Griddle User Manual


 
-
15 -
HELPFUL HINT – If the unit is attached to a flexible gas line, you can extend the bullet feet out to their
fullest extension to raise the griddle and allow yourself more clearance while reaching under the unit.
Remember to relevel the unit if you chose to do this.
BURNER
The RRG Series Griddle utilizes U-shaped burners with a single center inlet for every 12 inches of
griddle width. Each burner is rated for 27,500 BTU/hr.
Disconnect the electrical power and follow lockout / tagout procedures
BURNER TROUBLESHOOTING
SYMPTOM – ALL BURNERS HAVE A LOWER OR HIGHER FLAME THAN NORMAL.
1. Check gas pressure
SYMPTOM – ONE OR MORE BURNERS HAVE LOWER FLAME LEVEL THAN THE OTHERS.
1. Check gas pressure
2. Check burner orifice for obstructions
3. Adjust burner air shutter
4. Check solenoid valve
SYMPTOM – ONE BURNER HAS A DELAYED IGNITION; A SEVERAL SECOND LAPSE BETWEEN
THE INDICATOR LIGHT TURING ON AND WHEN THE BURNER ACTUALLY LIGHTS.
1. Check gas pressure
2. Check that burner locater pin is properly seated with retaining clip attached
3. Check that burner ignition ports, pilot flash tube and pilot burner are all aligned.
4. Check burner shutter adjustment
5. Check pilot flame adjustment
6. Check thermostat, safety ignition module and solenoid valve operation.
BURNER REMOVAL
Shut off gas supply
1. Remove the back panel