Vulcan-Hart 24RRG Griddle User Manual


 
-
4 -
GENERAL
INTRODUCTION
This manual is prepared for the use of trained service technicians and should only be used by those
who are properly qualified. This manual is not intended to be all encompassing. You should read, in
it's entirety, the repair procedure you wish to perform to determine if you have the necessary tools,
instruments and skills required to perform the procedure. Procedures for which you do not have the
necessary tools, instruments and skills should not be attempted.
Disconnect the electrical power and follow lockout / tagout procedures
Certain procedures in this manual require electrical test or
measurements while power is applied to the machine. Exercise extreme caution at all
times when attempting these procedures. Before testing, disconnect electrical power
and follow lock/out tagout procedures, then attach test equipment and reapply power to
test.
Procedures in this manual will apply to all RRG models unless specified. No procedure in this
manual will require the removal or raising of the griddle plate. Pictures and illustrations can be of any
model unless the picture or illustration needs to be model specific.
INSTALLATION
Generally, installations are made by the dealer or contracted by the dealer or owner. Detailed
installation instructions are included in the Installation and Operation Manual that is sent with each unit.
However, it should be noted that an improperly installed unit, especially an unlevel unit can lead to
premature electrical component failures. A unit that is higher in the front will cause the flue gases to
vent improperly and gather in the front near the electrical components. All RRG models must be
installed with an externally mounted regulator.
OPERATION
Detailed operation instructions are included in the Installation & Operation Manual sent with each
unit and are also available at WWW.VULCANHART.COM
.
CLEANING
Detailed cleaning procedures are included in the Installation & Operation manual sent with each
unit.
LUBRICATION
No lubrication is required on this equipment.
SPECIFICATIONS
All RRG models operate on 120 volt, 60 hertz, single phase at 1.0 amps. All models are equipped
with electric solid state thermostats, automatic spark igniters and pilot safety circuit. All models are
equipped with 27,500 BTU/HR burners as standard equipment. One burner is used for every 12 inches
of griddle surface. Natural gas models are to operate at 5.0" W.C. manifold pressure and LP models at
10.0" W.C. manifold pressure with all burners on.