Vulcan-Hart 48C Range User Manual


 
Fig. 23
4. Remove thermostat-combo valve from gas line
tubing.
5. Remove oven racks.
6. Open oven door and remove screws securing
capillary tube mounting clips (4) at the top of oven
cavity.
Fig. 24
NOTE: Capillary tube is permanently attached to
thermostat-combo valve.
7. Remove all mounting clips from capillary tube
and retain for reuse.
8. Pull capillary tube through the hole in oven
sidewall and remove thermostat-combo valve
from oven.
A. Remove insulation sleeve from capillary
tube for installation on replacement
thermostat capillary tube.
B. Note orientation of compression fittings on
valve body and remove for installation on
replacement valve body.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
When installing, do not bend and kink the
capillary tube or damage to the control may occur.
NOTE: When installing thermostat capillary tube,
push any insulation back through grommet and
remove loose insulation from oven cavity.
9. Reverse procedure to install and check for proper
operation.
CONVECTION OVEN BLOWER AND
MOTOR
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1. Remove cover from electrical junction box at the
rear of range.
2. Disconnect motor wiring at junction box.
3. Loosen screw securing armored cable to junction
box.
4. Remove oven racks and rack guides from oven.
5. Place cardboard over the oven cavity bottom to
protect it during motor removal.
6. Remove screws securing motor mount panel to
the oven. Pull the assembly out from the oven.
Fig. 25
7. Remove screws (4) securing blower cover to
motor mount panel.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
Page 13 of 38 F45471 Rev. A (0615)