Vulcan-Hart 52386 Pasta Maker User Manual


 
20
3. With
1
4" socket, remove (2) holding nuts and pull the relay off of the panel. (See Fig. 7)
4. Install new relay by reversing steps 1-3.
REMOVAL OF THERMOSTAT
1. Drain water from tank.
2. Follow steps 1- 5 under Removal of Cooker Control Panel.
3. Follow steps 1-4 under Removal Burner to remove the right hand burner from the cooker.
4. Follow the thermostat wiring to its mounting hardware under the tank assembly. With a
1
2" wrench, remove
the packing nut and with an
11
16" wrench remove the thermostat bulb mounting nut. Note that the thermostat
hardware is located toward the front of the tank. (Figs. 22)
Figs. 22
5. With a
1
4" socket, from inside the tank disengage the thermostat bulb from the tank mounting
brackets. (Fig. 23)
Fig. 23
HIGH LIMIT
Thermostat