MODEL C24EA - DOOR
F25213 (May 2006) Page 8 of 52
DOOR
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
REMOVAL
1. Close door.
2. Remove LEFT SIDE PANEL as outlined in
COVERS AND PANELS.
3. Remove nuts from upper hinge located inside
front panel.
4. Open door slightly, and while holding door, pull
upper hinge away from front panel.
5. Pull upper hinge out of upper door hinge
bushing.
6. Lift door assembly up and off lower door hinge.
7. Reinstall parts removed in reverse order of
removal.
8. Check door for fit and proper sealing of gasket.
GASKET
1. Open door.
2. Remove the shoulder screws and pan pusher
bracket from gasket plate.
3. Remove gasket plate.
4. Remove gasket from inner door panel.
5. Remove RTV from bottom part of inner door
panel. Apply new RTV 109 to bottom of door
where shown when assembling gasket to door.
6. Place a small amount of RTV109 into the inner
door panel gasket screw holes before
assembly.
7. Position the new gasket on gasket plate and
reverse procedure to install.