Vulcan-Hart C24S Range User Manual


 
CONVECTION OVEN BURNER
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Lower the KICK PANEL (24" & 30" OVENS).
2. Remove screws securing burner carrier to oven
frame.
Fig. 21
3. Pull burner carrier out through opening in lower
oven frame enough to access the oven pilot
assembly and burner elbow fitting.
4. Hold the tab on burner carrier with plyers to
support then remove compression nut from
burner elbow fitting.
5. Remove screws securing oven pilot assembly to
burner carrier. Move pilot assembly away from
burner.
Do not bend and kink the capillary tube or
damage to the control may occur.
6. Pull burner carrier with burner attached out from
oven.
7. Remove screws securing burner to the burner
carrier.
Fig. 22
8. Slide oven burner off the burner nozzle to
remove.
9. Reverse procedure to install.
10. Perform
BURNER AIR SHUTTER
ADJUSTMENT.
CONVECTION OVEN
THERMOSTAT-COMBO VALVE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove CONTROL PANEL (30" OVENS).
2. Remove compression nuts from thermostat-
combo valve fittings.
3. Remove screws securing thermostat-combo
valve to mounting bracket.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
F45471 Rev. A (0615) Page 12 of 38