11. Reverse procedure to install and check for proper
operation.
GRIDDLE GAS SAFETY VALVE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove CONTROL BRACKET.
2. Remove pilot tubing and thermocouple from gas
safety valve.
3. Remove compression nuts from gas safety valve
fittings.
Fig. 47
4. Remove screws (2) securing gas safety valve to
the control bracket and remove the valve.
A. Note orientation of compression fittings on
the valve and remove for installation on
replacement valve.
Fig. 48
When installing, do not bend and kink the
capillary tube or damage to the control may occur.
Clean pipe threads and apply pipe joint
compound. Any pipe joint compound used must be
resistant to the reaction of propane gases.
NOTE: When installing, ensure orifice hood is aligned
and centered in the burner assembly opening.
5. Reverse procedure to install and check for proper
operation.
GRIDDLE PILOT ASSEMBLY AND
THERMOCOUPLE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove CONTROL BRACKET.
2. Remove screws (2) securing pilot assembly
mounting bracket to griddle burner box.
A. If replacing thermocouple only, remove
thermocouple from pilot assembly and gas
safety valve. Continue to last step.
3. If replacing pilot assembly, remove pilot tubing
and thermocouple from pilot assembly.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
F45471 Rev. A (0615) Page 22 of 38