Vulcan-Hart C72SC Range User Manual


 
Fig. 35
3. Fully open door to check operation. If bottom
edge of door rubs the front edge of cavity bottom
then the swivel hinge is not engaged as
described.
A. To seat the swivel hinge, open door
approximately 30° and pull in the same
direction on the door handle. The hinge
should drop into place.
4. Open door and check operation. If okay, remove
bolts and close door. If not okay, remove door
and repeat installation procedure.
5. On convection ovens, verify door switch is
operating properly.
6. Reinstall oven control panel.
7. Raise kick panel.
GAS PRESSURE REGULATOR
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
1. Thread regulator onto pipe hand tight with arrow
pointing in direction of gas flow to the range.
Fig. 36
2. Tighten regulator securely in horizontal position
with the regulator adjustment upward as
described on regulator.
NOTE: Regulator will not function properly without
adjustment screw pointing upward.
3. Connect supply gas line to gas pressure
regulator inlet.
4. Adjust regulator as outlined in REGULATOR
ADJUSTMENT.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
F45471 Rev. A (0615) Page 18 of 38