Vulcan-Hart K6ETT Hot Beverage Maker User Manual


 
— 5 —
ELECTRIC TILTING COUNTER KETTLES
Before installing, verify that the electrical supply
required for the equipment covered by this
manual agrees with the specifications on the
machine data plate, located on the back of the
unit. The data plate for the kettle is located on
the control box. If the electrical supply does
not agree with the equipment requirements,
do not proceed with the installation. Contact
your dealer or Vulcan-Hart Company
immediately.
UNPACKING
This kettle was inspected before leaving the
factory. The transportation company assumes
full responsibility for safe delivery upon
acceptance of the shipment.
Immediately after unpacking, check for
possible shipping damage. If kettle damage is
found, save the packaging material and
contract the carrier within 15 days of delivery.
INSTALLATION CODES AND
STANDARDS
In the United States, Vulcan kettles must be
installed in accordance with:
1 State and local codes
2 NFPA Standard NFPA-96, Vapor Removal
from Cooking Equipment, latest edition,
available from the National Fire Protection
Association, Batterymarch Park, Quincy,
MA 02269
3 National Electrical Code (ANSI/NFPA
No.70, latest edition) available from the
National Fire Protection Association
(NFPA), Batterymarch Park, Quincy,
MA 02269
In Canada, Vulcan kettles must be installed in
accordance with:
1 Local codes
2 Canadian Electrical Code (CSA C22.2
No.3, latest edition) available from the
Canadian Standards Association, 5060
Spectrum Way, Mississauga, Ontario,
Canada L4W 5N6
LOCATION
The K6ETT and K12ETT tilting kettles are to
be permanently mounted on a counter or a
stand. The K20ETT is to be floor mounted.
MINIMUM CLEARANCE
TABLE 2. MINIMUM CLEARANCE
REQUIREMENTS
Capacity in Clearance in
Gallons Inches
6 5.25
12 6.5
20 8.0
INSTALLATION