Vulcan-Hart ML-52157 Range User Manual


 
– 10 –
5. The griddle plate is packaged separately from the range. On the top burner box front area of the
range, locate the coiled thermostat bulb and capillary assembly. Gently uncoil the capillary line.
Lift the griddle plate onto the range top, being careful not to crush the thermostat bulb or capillary.
Wedge a 2 x 4 under the front part of the griddle to hold up the plate. This will be necessary to install
the thermostat bulb into the V-slot bracket, located on the under side of the griddle plate.
6. Feed the thermostat bulb and capillary up over the heat shield and through the notched area
supplied in the shield (Fig. 16).
3. Triangle-shaped Bricks (4) — Place two each side (Fig. 15).
Fig. 15
4. Large Bricks (2) — Set in center support as shown in Figs. 14 and 15.
Fig. 16