Vulcan-Hart MSA36 ASA36 Griddle User Manual


 
-
7 -
GAS PRESSURE REGULATOR INSTALLATION
A gas pressure regulator is supplied with the griddle and must be installed. Install the
regulator as close to the griddle on the gas supply line as possible. Make sure that the
arrow on the underside of the regulator is oriented in the direction of gas flow to the
griddle (Fig. 2) and the regulator is positioned with the vent plug and adjustment screw
upright (Fig. 3). Check and set the gas pressure after the regulator is installed. The
pressure should be set for 4” water column (W.C.) for natural gas and 10” W.C. for
propane gas while all burners are on. It is recommended that a trained gas service
technician with the necessary tools, instruments and skills perform the installation of the
griddle and gas pressure regulator.
Fig. 2
Fig. 3
The supply pressure (upstream of the regulator) should be 7-9” W.C. for natural gas and
11-12” W.C. for propane gas. At no time should the griddle be connected to supply
pressure greater than ½ psig (3.45 kPa) or 14” W.C.
ELECTRICAL CONNECTIONS – 900RX MODELS
Electrical and grounding connections must comply with the
applicable portions of the National Electrical Code and/or other local electrical
codes.
Disconnect the electrical power to the griddle and follow lockout /
tagout procedures.
Appliances equipped with a flexible electric supply cord are provided
with a three-prong grounding plug. It is imperative that this plug be connected into
a properly grounded three-prong receptacle. If the receptacle is not the proper
grounding type, contact an electrician. Do not remove the grounding prong from
this plug.
Power supply for electric ignition is 120 volts, 1 amp, 50/60 Hertz, 1 phase.
Do not connect the griddle to electrical supply until after gas connections are made.