Vulcan-Hart VC6EC Convection Oven User Manual


 
FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
F25105 (December 2001)Page 11 of 60
1) Reverse procedure to install and
adjust blower position as outlined
under "BLOWER ADJUSTMENT" in
"SERVICE PROCEDURES AND
ADJUSTMENTS".
B. Motor
- perform step 3A and continue
procedure.
4. Remove the nuts that secure the motor
mounting plate to the rear wall.
5. Place a piece of cardboard on the bottom of
the oven cavity to protect its surface from any
damage during motor assembly removal.
6. Pull the motor assembly into the oven cavity
and place it on the cardboard.
7. Remove the junction box cover from the motor,
disconnect lead wires and remove the conduit.
8. Remove motor mounting bolts and flat washers
then lift the motor from the mounting plate.
9. Position the replacement motor on the motor
mounting plate and install mounting bolts and
washers.
Hand tighten mounting bolts only
.
10. Reconnect lead wires at the motor, replace
conduit and junction box cover.
NOTE:
Check data plate on motor for wiring
schematic. The motor must rotate clockwise
when
viewed from the shaft end.
11. Slide blower onto motor shaft until hub is flush
with end of shaft then tighten set screws.
12. Adjust motor position until blower is parallel to
motor mounting plate as outlined under
"BLOWER ADJUSTMENT" in "SERVICE
PROCEDURES AND ADJUSTMENTS".
13. Position motor mounting plate on the rear wall
and secure with nuts and washers.
14. Replace the baffle panel.
15. Remove cardboard from the bottom of the
oven cavity.
16. Check oven for proper operation then replace
rack guides and racks.
DOOR SWITCH
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1. Remove the top front cover as outlined under
"COVERS AND PANELS".
2. Disconnect the lead wires to the door switch.
3. Remove the switch.