Vulcan-Hart VC6EC Convection Oven User Manual


 
FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
F25105 (December 2001)Page 15 of 60
NOTE:
When installing probe guard, the probe
should not extend beyond the guard.
4. Remove the thermostat bulb from the oven
cavity by pushing it through the oven wall and
into the control panel area.
NOTE:
The hole in the oven cavity wall does not
line up straight with the oven cavity outer shell,
therefore the probe must be removed at an angle.
5. Reverse the procedure to install.
6. Adjust the thermostat as outlined under
"MECHANICAL (KX) THERMOSTAT
CALIBRATION " in "SERVICE PROCEDURES
AND ADJUSTMENTS".
HIGH LIMIT THERMOSTAT
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1. Take out racks from the oven.
2. Remove the high limit thermostat
cover/mounting plate from inside the oven
cavity at the top.
3. Disconnect lead wires from high limit
thermostat then remove high limit thermostat
from cover/mounting plate.
NOTE:
Remove the old RTV sealer from the cover
and mating surfaces inside the oven cavity and
apply new high temperature RTV sealer before
installing.
4. Reverse procedure to install.
INTERIOR LIGHTS
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
Lamp
1. Remove the racks.
2. Unscrew the glass lens for the light being
replaced then unscrew the bulb.
3. Replace bulb then reverse the procedure to
install.
Lamp Assembly
1. Remove the lens and bulb.
2. Remove the springs from the retaining tabs (2
places) on the socket.