Vulcan-Hart VHL3 & VH3616 Electric Steamer User Manual


 
– 30 –
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning this model, contact the Vulcan-Hart Service Agency
in your area (refer to our website, www.vulcanhart.com for a complete listing of Authorized Service and
Parts depots).
When calling for service, the following information must be available: model number, serial number,
manufacture date (MD) and voltage.
TROUBLESHOOTING
SYMPTOMS
High Pressure and Low Water lights do
not come on when [ l ] is pressed.
Steamer will not fill.
Steamer will not heat or build pressure.
Water flows into compartment.
Door leaks.
Water accumulates in compartment.
Water flows into drain when unit is off.
POSSIBLE CAUSES
1. Electrical power to the steamer is not on.
2. Power switch is not in the [ l ] position.
1.
If the Low Water light is on, the water supply valve
may be off. Check water supply pressure.
2. Water filter is plugged. Refer to water filter manual.
If symptom persists, contact Service.
1. Press Reset to clear any problem modes.
2. Water supply to the machine is not turned on.
3. Water filter may be clogged.
4. Make sure that both valves above and below the
sight glass are open.
5. Make sure that the water inlet ball valves are in the
open position.
Contact Service.
1.
Check door gasket for damage. If adjustment is
needed, contact Service.
2. Plugged drain or screen. Clear compartment cavity
screen. If symptom persists, contact Service.
Drain may be clogged. Clear drain.
Contact Service.