Vulcan-Hart VL3GSS ML-52393 Electric Steamer User Manual


 
– 16 –
WATER LEVEL GAUGE
Check the water level gauge sight glass daily. The correct water level is approximately 1" (
2.5 cm) of
water visible in the water level gauge sight glass. Extremely murky water in the sight glass indicates
bad water conditions. The boiler should be blown down. If conditions persist, have the boiler inspected
and cleaned by your local Vulcan-Hart servicer.
FLUE
Annually, when the steamer is cool, check the flue and clear any obstructions.
SCALE RELATED MAINTENANCE
Periodic maintenance is necessary to keep your boiler clean and efficient. Initially, after three months
of steamer usage, it is recommended that you have your Vulcan-Hart authorized servicer inspect the
boiler and perform the descaler maintenance described below. Local water conditions and steamer
usage will determine the frequency that this service must be repeated; however, a minimum
recommendation is once a year. This maintenance is not covered by warranty.
Cathodic protector(s) are provided inside the boiler to reduce boiler and component corrosion and
reduce accumulation of scale from forming on the boiler interior walls. The cathodic protector(s) will
be consumed. How fast the cathodic protector(s) will be consumed depends upon the chemical
makeup of the feed water and the average volume of feed water used. An inspection by service
personnel is recommended so that the expected normal life of the cathodic protector(s) can be
estimated under your operating conditions. Thereafter, the cathodic protector(s) can be serviced at
the appropriate frequency for your situation.
LUBRICATION
The door screw was factory lubricated with high-temperature grease, but will require periodic
relubrication by applying a bead of lubricant across the door handle screw threads. When the door
screw is properly lubricated, the hand pressure required to seal the door is greatly reduced and the life
of the screw and nut are lengthened. Frequency of lubrication depends upon use. Lubricate monthly
at first and let experience determine the frequency. A high-temperature grease for the door screw can
be obtained from Vulcan-Hart.
FORM 35409 Rev. A (Aug. 2004) PRINTED IN U.S.A.
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning this steamer, contact the Vulcan-Hart Service
Agency in your area (refer to listing supplied with the steamer), or contact the Vulcan-Hart Service
Department at the address or phone number shown on the front cover of this manual. Parts and service
manuals are also available at WWW.VULCANHART.COM
Symptoms Possible Causes
Steamer will not heat or build pressure. 1. Water supply to steamer is not turned on.
2. Water filter may be clogged.
3. Main gas supply valve may be turned off.
4. Electrical supply may be off or disconnected.
5. Combination gas valve may be turned off.
6. Ignition switch may be turned off.
Water accumulates in compartment. Drain may be clogged. Clear drain.
Other problems. Contact Service.
TROUBLESHOOTING