Vulcan-Hart VULCAN 36RB Oven User Manual


 
GAS PRESSURE REGULATOR
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
NOTE: Gas pressure regulator should be installed as
close to the broiler inlet gas connection as possible.
1. Thread regulator onto pipe hand tight with arrow
pointing in direction of gas flow to the broiler.
Fig. 30
2. Tighten regulator securely in horizontal position
with the regulator adjustment upward as
described on regulator.
NOTE: Regulator will not function properly without
adjustment screw pointing upward.
3. Connect main gas supply line to gas pressure
regulator inlet.
Fig. 31
4. Adjust regulator as outlined in
REGULATOR
ADJUSTMENT.
RACK SPRINGS
NOTE: Springs should be replaced in pairs for proper
operation of the rack lift assembly.
1. Remove crumb tray to access tension
adjustment nuts from the front of broiler.
2. Raise the rack lift assembly to its highest position
on stop plate to relieve spring tension.
3. Loosen nuts to remove any remaining tension on
springs.
4. Access the bottom of broiler and remove springs
from the lower arm casting and eye bolt.
Fig. 32
5. Reverse procedure to install.
6. Perform
RACK SPRING TENSION
ADJUSTMENT.
SALAMANDER BROILERS RADIANT AND INFRARED - REMOVAL AND REPLACEMENT OF PARTS
F45530 (0814) Page 12 of 17