Waterford Appliances Free Standing Refrigerator Refrigerator User Manual


 
When the cooling fan is not switched on, the natu-
ral circulation of air within the refrigerator chamber
will cause different temperature zones. This
caused by the cold air sinking to the lowest section
of the chamber. This should be kept in mind when
loading the refrigerator (see Using the Refrigerator
Efficiently.
Brief Temperature Variation
Brief temperature variation may occur when the
refrigerator door is open during loading. These
variations will not affect the food and the tempera-
ture will quickly return to its preset value.
Display Brightness Adjustment
There are 3 different options to adjust the bright-
ness of the display;
* 1.8 minimum brightness
* 2.8 medium brightness
* 3.8 maximum brightness (default setting)
To adjust:
Press and hold the
CL
button (11). Press the
button (6) to increase and the
decrease brightness.
Error
Codes
Type Description
E1 Temperature
sensor fault in the
refrigerator
chamber
Sensor has been
damaged. Call a qual-
ified technician. The
built-in emergency
program will maintain
an adequate tempera-
ture until the fault has
been removed.
E4 Door open The refrigerator door
has been open for
more than 3 minutes
Interrupting The Alarm
The alarm can be interrupted by opening and clos-
ing the door or by pressing any buttons on the
control panel for 7-8 seconds.
In case of error E1, the fault can only be stopped
when the damaged sensor has been replaced.
Storage Zones In The Refrigerator
Due to natural circulation of the air in the appliance, there are different temperature zones in the refrigerator
chamber.
USING THE REFRIGERATOR EFFICIENTLY
11
button (7) to
Alarm and Error Codes