Wells F-55 Fryer User Manual


 
DESCRIPTION POSSIBLE PROBLEM SUGGESTED REMEDY
Fryer will not heat Not plugged in or circuit breaker
tripped
Plug into proper receptacle
Reset circuit breaker
Temperature control knob not set to
desired temperature
Set to desired temperature
Hi-limit safety tripped Clean element
1
, reset hi-limit
Damaged internal component Contact Wells Authorized Service
Agency for repairs
Fryer will not maintain
temperature
Temperature control thermostat
thermobulb contaminated with
cooking debris
Clean element
2
Damaged internal component Contact Wells Authorized Service
Agency for repairs
Fryer leaks oil Damaged frypot Contact Wells Authorized Service
Agency for repairs
Element head will not
raise, will not stay in the
up position, or will not
lower
Frypot out of position, or has excess
cooking debris in bottom
Check frypot for position
Clean frypot
1
The hi-limit safety is designed to shut down the fryer if the oil temperature exceeds 440ºF. A build-up
of cooking debris between the heating element and the thermobulb of the hi-limit safety will cause the
hi-limit to trip prematurely. Clean the element so that oil may circulate freely between the element
and the thermobulb. Reset the safety by pressing the red button on the bask of the element head.
2
A build-up of cooking debris between the heating element and the thermobulb temperature control
thermostat will cause inconsistent temperatures. Clean the element so that oil may circulate freely
between the element and the thermobulb.
TROUBLESHOOTING SUGGESTIONS
9
Damaged hinge bracket or support
rod
Contact Wells Authorized Service
Agency for repairs