INSTALLATION
4
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
REFER TO EXPLODED VIEWS PAGE 9 FOR COMPONENT
NAMES/NUMBERS
Unpack the unit. Inspect all components for completeness and
condition. Ensure that all packing materials have been removed
from the unit.
LEVELING THE UNIT
Verify that a slip-resistant foot is installed at each corner of the
dispenser.
Set the warmer in its operating location. Be sure all four feet
touch the counter to prevent tipping.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the warmer.
Models HD8799 and HD8802 dispensers are equipped with a
cord and plug. They requires a 115 - 125 volt circuit (50/60 Hz,
2 wire plus ground, with NEMA 5-15R receptacle).
IMPORTANT: The ground prong of the plug is part of a system
designed to protect you from electrical shock in the event of
internal damage. Never cut off the ground prong nor twist a
blade to fit an existing receptacle. Contact a licensed electrician
to install the proper circuit and receptacle.
CAUTION: Equipment
Electrical Damage
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and
followed. Damage to the
Brewer will occur if these
instructions are not followed.
CAUTION: Unstable
Equipment Hazard
It is very important for safety
and for proper operation that the
warmer is level and stable when
standing in its final operating
position. Provided non-skid feet
must be installed at each corner
of the unit. Do not install this
appliance if the feet are missing
or damaged.
WARNING ELECTRIC
SHOCK HAZARD:
Warmer must be properly
grounded to prevent possible
shock hazard. Electrical shock
will cause death or serious
injury.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
warmer or result in decreased
performance. Such damage is
not covered by warranty.
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PIN