ELECTRICAL INSTALLATION
Refer to the nameplate on the front of the fryer and to the specifications
listed on page 1 of this manual. Verify that electric service voltage,
phase and amperage capacity meet or exceed these specifications.
Field wiring must be no less than 4 ga. solid copper wire, rated for at
lease 90ºC.
Fryers are shipped from the factory wired for 3Ø. Fryer is not approved
for conversion to single phase.
IMPORTANT:
Field wiring must be routed and secured away from the FRYPOT,
TUBING and FILTER PUMP MOTOR. Field wiring must be configured
to allow access to the rear of fryer for cleaning and access to the filter
pump motor RESET BUTTON.
INSTALLATION (continued)
9
IMPORTANT:
Electric installation of this
appliance must be performed
by a licensed electrician.
Installation must conform to
the requirements of local
codes and ordinances, and to
the requirements of the
National Electrical Code.
IMPORTANT:
This appliance is rated for
3Ø electric service only, and
is not UL approved for single
phase operation. DO NOT
convert this appliance to
single phase. Doing so will
void the warranty and
invalidate the UL listing.
Fig. 2 Field Wiring
363 30007 OpManual for WFAE-55F/FS Electric Fryer
POWER
CORD
FILTER
PUMP &
MOTOR
FRYPOT
STRAIN
RELIEF
FITTING