“A” = 30” MIN. CLEARANCE BETWEEN
THE TOP OF THE COOKING PLATFORM
AND THE BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET.
“A” = 24” MIN. WHEN BOITOM OF WOOD
MILLBOARD COVERED WITH NOT LESS
THAN NO. 28 MSG. SHEET STEEL, 0.015”
STAINLESS STEEL. 0.024” ALUMINUM OR
0.020” COPPER.
CAUTION: To eliminate the hazard of reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet
storage is to be provided, the hazard can be reduced by
installing a range hood that projects horizontally a
minimum of 5 inches beyond the bottom of the cabinets.
28%” WRAP TO WRAP
INCLUDING SCREW HEADS
LOCATE ELECTRIC 41.
ON FLOOR OR 014
REAR WALL NEP. 1
FLOOR LINE.
CUTOUT AND HINGE OR DOOR
WALL LINE
**
2&l/2” MINIMUM, IF 2E5/B”
IS AVAILABLE THE CUTOUT
SHOULD BE MADE 285/B”.
NOTE: ON CABINET TOPS WITH
FORMED FRONT EDGE, SHAVE
RAISED SECTION TO CLEAR
3(r WIDE RIM. (SEE SKETCH BELOW)
FRONT VIEW
FIGURE 1 --ROUGH-IN DIMENSIONS
NOTE:
The Installation must conform to any local codes. The
Set-In Unit may be mounted and secured to the cabinet
similar to regular built-in equipment.
1. CARPENTRY
Prepare the cut-out space, shown in Figure 7, in the
desired location in the counter top and cabinet. The
support surface (4%” high) must be solid and level from
side to side and front to rear. A minimum of 7/g” of
cabinet area on either side of cut-out should be clear
of handles, hinges or any other obstruction.
2. ELECTRICAL REQUIREMENTS
IMPORTANT: OBSERVE AU GOVERNING CODES
AND ORDINANCES
SAVE THESE INSTRUCTIONS FOR THE LOCAL:
ELECTRICAL INSPECTOR‘S USE
.I
A. A three-wire or four-wire single phase 120/240 vat t
60Hz AC only electrical supply (or three-wire
cr
four-wire 120/208 volt if specified on nameplate) II ;
required on a separate circuit fused on both side j
of the line (time-delay fuse or circuit breaker ii
recommended). Do NOT fuse neutral. The fuse siz: ?
must not exceed the circuit rating of the appliancl3
specified on the nameplate.
NOTE: Wire sizes and connections must conforr 1
with the fuse size and rating of the appliance iI1
accordance with the National Electrical Code ant f
local codes and ordinances. Do not use ali
extension cord.
2