Whirlpool 4454653 Cooktop User Manual


 
Electrical
Electrical
requirements connection
Electrical Shock Hazard
Electrically ground cooktop.
Failure to follow this instruction could
result in death, fire, or electrical shock.
If codes permit and a separate
grounding wire is used, it is
recommended that a qualified
electrician determine that the
grounding path is adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you
are not sure the cooktop is properly
grounded.
Do Not have a fuse in the neutral or
grounding circuit.
IMPORTANT:
Save Installation Instructions for electrical
inspector’s use.
A
n
A three-wire, single-phase,
240-volt, 60-Hz, AC-only electrical supply
is required on a separate, 40-ampere
circuit, fused on both sides of the line.
A time-delay fuse or circuit breaker is
recommended. The rating of the fuse or
circuit breaker should be equal to the
marked current rating (amps) on the
appliance, but not larger than the nex-t
standard fuse or circuit breaker size. The
marked current rating is specified on
the model/serial rating plate located on
the bottom of the cooktop.
B
n
THE COOKTOP MUST BE
CONNECTED WITH COPPER WIRE ONLY
C
l
Wire sizes and connections
must conform to the requirements of
the National Electrical Code ANSVNFPA
70 - latest edition**, or CSA Standards
C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. O-M91 - latest
edition*** and all local codes and
ordinances.
Copies of the standards listed may be obtained
from:
l
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
l
** Canadlan Standard Assoclatlon
178 Rexdale Boulevard
Etobicoke (Toronto), Ontario M9W lR3
D
n
The cooktop should be
connected directly to the fused
disconnect or circuit breaker box
through flexible, armored or non-
metallic sheathed, copper cable. The
flexible, armored cable extending from
the fuse box or circuit breaker box
should be connected directly to the
junction box.
E
n
Locate the junction box to
allow as much slack as possible
between junction box and the cooktop
so that the cooktop can be moved if
servicing is ever necessary. Do Not cut
the conduit.
Electrical Shock Hazard
Disconnect power to the junction box
before making connection.
Electrically ground cooktop.
Failure to follow these instructions
could result in death, fire, or electrical
shock.
This cooktop must be connected to a
grounded, metallic permanent wiring
system or a grounding connector
should be connected to the grounding
terminal or wire lead on the cooktop.
This cooktop is manufactured with a
frame-connected, green or bare
grounding wire.
Connect the cooktop cable to the
junction box through the U.L.-listed or
C.S.A.-listed conduit connector.
Complete electrical connection
according to local codes and
ordinances.
A
n
Where local codes permit
connecting the frame-grounding
conductor to the neutral (white) junction
box wire: (Not used for Canadian
installations).
cable from
power supply
I I
JunFtion box
red wires
AL /
white wire
II
Y/
bare or’
green wire
U.l.-or C.S.A.-listed
conduit connector
cable from cooktop
Grounded neutral
Figure 1
1. Disconnect power supply.
2. Connect the flexible armored cable
from the cooktop to the junction box
using a U-L.- or C.S.A.-listed conduit
connector. Tighten screws on conduit
connector.
3. Connect the green (or bare)
appliance cable wire with the neutral
(white) wire in the junction box.
4. Connect the two black wires
together; then connect the two red
wires together with twist-on wire
connectors. (See Figure 1.)
B
n
Where local codes Do Not
permit connecting the frame-grounding
conductor to the neutral (white)
junction box wire: (Used for all
Canadian installations).
cable from power supply
I I
iunctlon box
bare or
green wires
conduit connector
cable from cooktop
Ungrounded neutral
Figure 2
1. Disconnect power supply.
2. Connect the flexible armored cable
from the cooktop to the junction box
using a U.L.- or C.S.A.-listed conduit
connector. Tighten screws on conduit
connector.
3. Connect the two black wires
together; then connect the two red
wires together with twist-on wire
connectors. (See Figure 2.)
4. Connect the green (or bare)
grounding wire from the appliance
cable to the grounded wire in the
junction box or other grounded
connector.
5. Put a twist-on wire connector on end
of white wire.
F
n
A U.L.- or C.S.A.-listed conduit
connector must be provided at each
end of the power supply cable (at the
cooktop and at the junction box).
Panel B