7
junction box
4-wire cable from power supply
twist-on
connector
black wires
U.L.- or CSA- listed
conduit connector
bare or green
wires
white wire
red wires
For all cooktop models with three-wire cable from the cooktop:
Where local codes Do Not permit connecting the frame-
ground conductor to the neutral (white) junction box
wire. (Used for Canadian installations):
1. Disconnect
power supply.
2. Remove the junction
box cover from the junction box inside the cabinet.
3. Connect the flexible, armored cable from the cooktop to the
junction box using a U.L.- or CSA-listed conduit connector.
Tighten screws on conduit connector.
4. Connect the two black wires together; then connect the two red
wires together using twist-on connector. (See Figure 1.)
5. Connect the green or bare ground wire from the cooktop cable
to the grounded wire in the junction box or other grounded
connector using twist-on connector.
6. Put a twist-on connector on end of white wire. Do Not connect
bare ground wire to neutral (white) wire in junction box.
7. Replace the junction box cover.
Ungrounded
neutral
3-wire cable
from cooktop
3-wire cable from power supply
junction box
black wires
twist-on
connector
U.L.- or CSA- listed
conduit connector
3-wire cable
from cooktop
bare or
green wire
white wire
red wires
Where local codes permit connecting the frame-ground
conductor to the neutral (white) junction box wire. (Not
used for Canadian installations):
1. Disconnect
power supply.
2. Remove the junction box cover from the junction box inside
the cabinet.
3. Connect the flexible, armored cable from the cooktop to the
junction box using a U.L.- or CSA-listed conduit connector.
Tighten screws on conduit connector.
4. Connect the bare cooktop wire with the white wire; the two
red wires together; and the two black wires together using
twist-on connectors. (See Figure 2.)
5. Replace the junction box cover.
Grounded
neutral
Figure 2
Grounded
neutral
Figure 4
Where local codes Do Not permit connecting the frame-
ground conductor to the neutral (white) junction box
wire: (Used for Canadian installations):
For all cooktop models with four-wire cable from the cooktop. (These cooktops are manufactured with white
[neutral] power supply wire and a cabinet-connected bare ground wire factory-crimped together.):
1. Disconnect
power supply.
2. Remove the junction
box cover from the junction box inside the cabinet.
3. Connect the flexible, armored cable from the cooktop to the
junction box using a U.L.- or C.S.A.-listed conduit connector.
Tighten screws on conduit connector.
4. Connect the two black wires together; then connect the two red
wires together using twist-on connectors. (See Figure 3.)
5. Separate the factory-crimped bare and white cooktop cable wires.
6. Connect the two white wires together using twist-on connectors.
7. Connect the bare ground wire from the cooktop cable to the
grounded wire in the junction box or other grounded connector
using twist-on connector. (See Figure 3.)
Do Not connect bare ground wire to neutral (white) wire in
junction box.
8. Replace the junction box cover.
Figure 1
Ungrounded
neutral
Figure 3
junction box
4-wire cable from power supply
twist-on
connector
black wires
U.L.- or CSA- listed
conduit connector
bare or
green
wires
white wires
red wires
4-wire cable
from cooktop
Where local codes permit connecting the frame-ground
conductor to the neutral (white) junction box wire. (Not
used for Canadian installations):
1. Disconnect
power supply.
2. Remove the junction
box cover from the junction box inside the cabinet.
3. Connect the flexible, armored cable from the cooktop to
the junction box using a U.L.- or C.S.A.-listed conduit
connector. Tighten screws on conduit connector.
4. Connect the two black wires together; the two red
wires together; and the factory-crimped bare and
white cooktop cable wires to the white (neutral) wire
in the junction box using twist-on connectors. (See
Figure 4.)
5. Replace the junction box cover.
junction
box
red
wires
white
wire
white and bare
grounding oven cable
wires — factory
crimped
3-wire cable from
power supply
black
wires
4-wire cable from cooktop
U.L.- or CSA-
listed conduit
connector
YK20519/8285116 Eng 11/18/02 2:52 PM Page 7