Whirlpool IH7302RS0 Ventilation Hood User Manual


 
8
4. Level the hood with leveling screws in mounting hooks or
rectangular cutouts, using a level across bottom of hood.
5. Secure hood with 4 screws through remaining 4 holes in hood.
Install Vent
Vented Installations
1. Fit vent system over transition piece.
2. Seal connection with duct tape.
Non-Vented (Recirculating) Installations
Install the deflector inside lower vent cover with screws provided.
A. Deflector
A
B
B
D
C
A
B
A. Mounting hooks
B. Mounting screws
C. Leveling screws
D. Centerline on wall
A
A. Vent system
B. Transition
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in terminal box cover and install the
UL- or CSA-listed ¹⁄₂" conduit.
4. Run 3 wires, black, white and green (14 AWG) in ¹⁄₂" conduit
from service panel to terminal box.
5. Use twist-on connectors and connect black wires together.
6. Use twist-on connectors and connect white wires together.
7. Use twist-on connectors and connect green or bare wire with
yellow-green wire.
8. Replace terminal box cover.
9. Check all light bulbs to make sure they are secure in their
sockets.
10. Reconnect power.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
A. Conduit
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.