Whirlpool IH7302RS0 Ventilation Hood User Manual


 
Complete Installation
1. Install vent cover.
When using both upper and lower vent cover, push lower
cover down onto hood and lift upper cover to ceiling and
install screws.
For reduced ceiling height installations, when using only
the lower cover, push lower cover down onto hood and
snap vent into place around vent cover bracket.
Install Filters
1. For non-vented (recirculating) installations, install charcoal
filter over grill on blower housing and turn filter handle
clockwise. Repeat with other charcoal filter.
2. For all installations, insert back edge of metal filter into rear
channel of the filter opening.
3. Push handle toward the rear and push filter up.
4. Pull filter toward the front and insert into front channel.
A
B
C
C
A. Blower housing
B. Handle
C. Charcoal filters
B
A
Check Operation
1. Check operation of the range hood by turning the power on.
2. Move the light switch to the “1” position. The light should
turn on.
3. Move the light switch to the “0” position. The light should
turn off.
4. Move the blower switch to the “1” position for low speed.
“2” position for medium speed. “3” position for high speed.
5. Move the blower switch to the “0” position. The blower
should turn off.
6. If range hood does not operate, check that the circuit breaker
has not been tripped or the house fuse blown. Disconnect
power supply and check that the wiring is correct.
OI O123
A
A. Light switch
B. Blower switch
B
A. Upper vent cover
B. Lower vent cover
9