Whirlpool CHCH8AS Ice Maker User Manual


 
FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE CODES
It
IS
the personal responslbrlrty and oblrgatlon of the
cuslomer to contact a qualIfted installer to assure that the
electrtcal rnstallatron IS adequate and IS In conformance
with the National ElectrIcat Code and local codes and
ordrnances
NOTE:
A separate circuit must be used with 20 ampere
time delay fuses.
REMOVE TOP SHROUD
1. Loosen screws on lower front corners of shroud.
2. Pull complete shroud forward and lift off.
CAUTION: Use proper care when handling this awkward
part.
INSTALL GROUNDING WIRE
COPPER WIRE ONLY
1. Permanently ground this Ice maker In accordance
with the National ElectrIcal Code and local codes and
ordinances GROUND MUST BE CONTINUOUS
2. Use a copper conductor of the appropriate size
from the Ice maker green grounding wrre to a grounded
connectlon In the service panel or a properly driven and
electrlcally grounded rod
3. Replace electrical junction box cover
4. Replace shroud.
Alternate (Not Recommended)
1. If the recommended grounding method IS Impossible.
permanently ground the appliance from the green ground-
ing screw to a grounded cold water plpe*usrng a separate.
green colored, insulated copper conductor of appropriate
size THIS. HOWEVER IS NOT RECOMMENDED
NOTE: Do not ground to a gas supply pipe Do not con-
nect to electric power supply until applrance IS perma-
nently grounded
INSTALL ELECTRICAL WIRING
COPPER WIRE ONLY
115-2081230 V, 3-Wire, 60 Hz, 1 Ph,
20 Amp Time Delay Fuses
Install wiring according to Local and National Electrical
Codes into junction box provided at rear of cabinet. Replace
electrical box cover and shroud.
PROVIDE A FUSED DISCONNECT BOX WITHIN
SIGHT AND EASY REACH OF THE ICE MAKER.
Be sure power supply is within + 10% - 5% of recommended
voltage when machine is in operation.
ICE MAKER
ELECTRICAL
JUNCTION BOX
:I
TO SERVICE
PANEL
DISCONNECT
AMP TIME
LAY FUSES
*
Cold water pipe
must have
metal continuity to electrical ground and
not be interrupted by plastic, rubber or other electrically insulating
connectors (including water merer or pump) without adding a copper
jumper wire at these connections.