Whirlpool ECKMF-281 Ice Maker User Manual


 
Connect Ice-Maker
To Water (Contd.)
1.
2.
3.
4.
5.
6.
Find a %-inch to 1 -inch vertical COLD water pipe near
the refrigerator. (Horizontal pipe will work.. but extra
precautions must be taken.) (See in Step 4.)
Measure from inlet on rear of refrigerator to water pipe.
Add 7 feet to allow for moving refrigerator for cleaning.
This is the length of %-inch O.D. copper tubing you
will need for the job (length from inlet tube to water
pipe PLUS 7 feet). Be sure both ends of copper tubing
are cut square.
Turn OFF main water supply. Turn ON nearest faucet
long enough to clear line of water.
Using a grounded drill, drill a 3/16-inch hole in the
vertical cold water pipe you have selected.
Some water almost always remains in pipes. If it
enters the drill, it can cause lethal shock. BE SURE
YOUR DRILL IS GROUNDED.
Fasten a separate ground wire from drill to a good
ground that complies to local electrical codes. (If in
doubt, consult a licensed electrician.) UNLESS
PROPER GROUNDING IS FOLLOWED, YOU ARE
NOT PROTECTED AGAINSTSEVERE OR LETHAL
SHOCK.
l
If you must use a horizontal pipe, take extra
precautions:
Drill on the top or side of the pipe, not bottom.
This helps keep water away from the drill. Also, it
keeps normal sediment from collecting in the valve.
Fasten shutoff valve to cold water pipe with pipe
clamp. Be sureinlet end is solidly in the 3/16-inch drilled
hole in the water pipe and that washer is under the
pipe clamp. Tighten packing nut. Tighten the pipe
clamp screws carefully and evenly so washer makes
a watertight connection. Do not overtighten or you
may crush copper tubing, especially if soft copper
tubing is used. Now you are ready to connect the
copper tubing.
Slip compression nut and compression sleeve on
copper tubing as shown in diagram. Insert end of
tubing into out/et end squarely as far as it will go.
Screw compression nut to outlet end with adjustable
wrench. Do not overtighten. Turn ON main water
supply and flush out tubing until water is clear. Turn
OFF shutoff valve on the water pipe. You are now
ready to connect other end of %-inch copper tubing
to
inlet tube or water valve on back of refrigerator.
7. Assemble compression nuts on tubing as shown in
diagram. Insert ends of tubing into connector and
tighten compression nuts. Be sure ends of tubing are
squarely in connector as far as they will go. Do not
over-tighten.
‘/!I” TUBE TO
SHUTOFF VALVE
CONNECTOR
SLEEVE
NUT
WATER VALVE TUBE
Step 7
8. Turn shutoff valve on. TIGHTEN ANY CONNEC-
TIONS OR NUTS THAT LEAK.
9. Copper tubing may now be fastened to baseboard.
10. The Ice Maker has a built-in water strainer on the inlet
side of the water valve. Use a second water strainer
when local water conditions require periodic cleaning
or a well is your source of water. The strainer can be
installed in the X-inch water line.
11. Water pressure should not be below (15 P.S.I.) or
above (125 P.S.I.). If problem occurs call your Utility
Company.
12. PLUG IN YOUR REFRIGERATOR.
When you have your first batch of ice you may throw
away extra parts.
IMPORTANT:
It may take up to 24 hours for your Ice Maker to begin
producing ice crescents.
To enjoy your Ice Maker most PLEASE READ CARE-
FULLY THE ICE MAKER SECTION OF YOUR USE AND