5. Electrical Requirements
Observe all governlng codes and ordinances.
A 120 mlt, 60 Hz, AC only, 15 or 20 amp fused eleatrlcal supply Is required. (Tlme-
delay fuse Is recommended). It is recommended that a separate clrcult serving only
this appliance be provlded.
6.GROUNDING INSTRUCTIONS
WARNING
. Improper use of the grounding plug can result In a risk of
. electrlcal shock.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER
SUPPLY CORD GROUNDING PRONG.
7. For your personal safety, this appliance must
wall receptacle is properly grounded and
be grounded. In the event of an electrical short
polarized, have it checked by a qualified
circuit, grounding reduces the risk of electric electrician.
shock by providing an escape wire for the elec-
tric current. This appliance is equipped with a
It is the personal responsibility and obligation of
the customer to have a properly grounded and
3-PRONG \
correctly polarized J-prong wall receptacle
GROUNDING TTPE
0
installed by a qualified electrician.
WALL RECEPTACLE
QQ
Consult a qualified electrician if the grounding
instructions ore not completely understood, or if
3-PRONG
doubt exists as to whether the appliance is
GROUNDING PLUG
0
1[1
0
cj
properly grounded.
\
It
is
NOT recommended to use an extension
/J =--
r
cord with your microwave oven, but if you find
it necessary to do so temporarily (until a pro-
I ’
I f
perly grounded and polarized 3-prong recepta-
‘OWER SUPPLY ’
CORD \
GROUNDING
cle is installed), use only a heavy duty UL listed
PRONG
3
wire
grounding type extension cord containing
Dolarized 3-proig grounding plug. It must be
three 16 gauge (minimum) copper wires.
It must
not be longer than10 feet (cords longer than 10 feel
Dlugged into a correctly polarized mating 3-
may affect the cooking petformance of your mt-
Drong grounding type wall receptacle, prop-
crowove oven). The plug on the extension cord
?rly installed and grounded in accordance
must fit into a 3-prong grounding type wall recep-
Nith the National Electrical Code and local
tacle (as shown on this page] and the receptacle
:odes and ordinances. If a mating wall recep-
end of the extension cord must accept the 3-prong
acle is not available or if you are not sure if the grounding plug of the microwave oven.
8. Plug the oven into the proper elec-
trical outlet and put about one cup
(250 ml] of cold water in a glass container in the
9. This microwave oven is designed for use in
the household only and must not be used for
commercial purposes.
&en. C&e the door. Make sure it latches. Fol-
low the directions on page 6 to set the oven to
COOK for 2 minutes. When the time is up, the
water should be heated.
DO NOT remove the door, control panel, or
cabinet at any time. The unit is equipped with
high voltage and should not be serviced unless
bv an authorized Whirlpool trained service
technician.
SAW THESE INSTRUCTIONS
9