5. Align the range hood front panel with the cabinet. Slide the
screen forward. Locate the 2 screws on each side and turn
them counterclockwise to loosen the screws. Adjust the front
of the vent vertically, ³⁄₈" (9.5 mm) up or down, or horizontally,
³⁄₄" (19 mm) front to back, until the front is flush with the
cabinet. Tighten the screws. If it is necessary to adjust the
given dimensions, lower and add or remove the filler strips or
redrill mounting holes.
Electrical Connection
1. Disconnect power.
2. Use UL listed wire connectors and connect black wires (D)
together.
3. Use UL listed wire connectors and connect white wires (A)
together.
4. Connect the green (or bare) ground wire from the home
power supply to the green ground screw inside the range
hood terminal box.
5. Tighten strain relief screw.
6. Install terminal box cover.
Connect the Vent System
Vented Installations
1. Replace the metal filters. See “Range Hood Care” section.
2. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
3. Reconnect power.
4. Check the operation of the range hood fan and light.
5. Push the range hood screen back in.
Non-Vented (recirculating) Installations
1. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
2. Install Charcoal Filter Kit Part Number 883140. See “Range
Hood Care” section.
3. Replace metal grease filters. See “Range Hood Care”
section.
4. Reconnect power.
5. Check the operation of the range hood fan and light.
6. Push the range hood screen back in.
To order replacement kits, see the “Assistance or Service”
section.
A. Phillips screwdriver
B. Adjustment screws
A. White wires
B. Green ground screw
C. Ground wire
D. Black wires
E. Wire connectors
A
B
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
E
B
C
D
A
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.