Whirlpool UXT3036AY Ventilation Hood User Manual


 
8
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Wall Venting
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring ³⁄₈" (0.9 cm) and 3⁷⁄₈" (9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to Round Vent Transition
Roof Venting
To make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines ¹⁄₂" (1.3 cm) and 4³⁄₄" (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Install Vent System
1. Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See “Venting Requirements” section.
2. Use caulking to seal exterior wall or roof opening around the
cap.
Install Range Hood
NOTE: Your model will have a 3¼" x 10" (8.3 x 25.4 cm)
rectangular vent connector on the inside of the range hood.
1. Remove the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent
connector attached with 3.5 x 9.5 mm screws on the inside
your range hood. Use these screws to install the rectangular
vent connector.
5¹/"
(13.3 cm)
5¹/"
(13.3 cm)
*4³⁄₄"
(12.1 cm)
*From wall, not cabinet frame
Cabinet cutouts
*¹⁄₂" (1.3 cm)
³⁄₈"
3⁷⁄₈"
Cabinet
front
(0.9 cm)
(9.8 cm)
5¹⁄₄"
(13.3 cm)
Centerline
5¹⁄₄"
(13.3 cm)
5¹/"
(13.3 cm)
5¹/"
(13.3 cm)
*4³⁄₄"
(12.1 cm)
*From wall, not cabinet frame
*¹⁄₂" (1.3 cm)
A. 3
¹⁄₄
" X 10" (8.3 X 25.4 cm) rectangular vent connector
B. Screws
Circular vent opening
Cabinet
cutouts
*From wall, not
cabinet frame
*5"
(12.7 cm)
A
B