Whirlpool UXT4230AD Ventilation Hood User Manual


 
10
5. Remove vent knockouts depending on your installation
requirements.
Round vent system installations - Remove top rectangular
and round vent knockouts.
Rectangular vent system installations - For roof
installations, remove the top rectangular vent knockout. For
wall installations, remove the rear rectangular vent knockout.
Non-vent (recirculating) installations - Do not remove any
knockouts.
6. Install 7" (17.8 cm) round vent mounting plate or 3¼" x 10"
(8.3 x 25.4 cm) vent damper, depending on your vent system
installation. Attach to range hood 3.5 x 9.5 mm screws
provided.
NOTE: The 7" (17.8 cm) round vent mounting plate is not
supplied. An optional 7" (17.8 cm) round damper is also
available as an accessory. For information on ordering, see
the “Accessories” section.
NOTE: The 7" (17.8 cm) round vent mounting plate and
3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent damper can be
installed up to 1" (2.5 cm) on either side of the hood
center to accommodate off center ductwork.
If a vent damper is installed with a wall cap with damper,
check that they do not interfere with each other. Remove
the vent connector damper flap if they interfere.
Non-vented (recirculating) installations - No vent
attachments. Removal of the recirculation cover plate is
required. Remove the two screws from the recirculation
cover plate and remove.
A. Round vent knockout
B. Top rectangular vent knockout
C. Rear rectangular vent knockout
A. 7" (17.8 cm) Round damper (see “Accessories” section)
B. 3.5 x 9.5 mm screws
C. 7" (17.8 cm) round vent mounting plate. For information
on ordering, see the “Accessories” section.
D. Round vent knockout
E. Rectangular vent knockout
A
B
C
A
B
C
D
E
A. Vertical damper
B. 3.5 x 9.5 mm screws
C. Vent knockouts
D. Horizontal damper
A. Recirculation cover plate
B. Screws
A
B
C
B
D
A
B