17
4. Remove the cap from the gas pressure regulator using a flat-
blade screwdriver.
5. Turn the cap over so that “N” or “NAT” is visible.
6. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners.
2. Locate the Natural gas orifice spuds for top burners in the
package containing literature included with the range. Three
Natural gas spuds are stamped “149” and one “165.”
3. Remove the LP gas orifice spuds using a 7 mm combination
wrench.
4. Install the Natural gas orifice spuds using a 7 mm
combination wrench.
NOTE: Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and
1 super burner. Spud size and location remain the same.
For models with 4 standard burners:
For models with 3 standard burners and 1 super burner:
5. Place LP gas orifice spuds in the parts bag for future use and
keep with the package containing literature.
6. Reinstall burners, burner caps and burner grates.
A.Cap
A.Cap
A.Burner cap
B.Burner
A
A
A
B
A.Spud
B.Holder
A
B
Std Burner 149
Std Burner 149
Std Burner 149
Std Burner 149
Std Burner 149
Std Burner 149
Std Burner 149
Super Burner 165