Whirlpool WRV976FDEM Refrigerator User Manual


 
222222222222
Water and Ice Dispensers
IMPORTANT:
Allow 3 hours for the refrigerator to cool down and chill water.
Allow 24 hours to produce the first batch of ice. Discard the
first three batches of ice produced.
The dispensing system will not operate when either the
refrigerator door or freezer drawer is open.
Flush the Water System
Air in the water dispensing system can cause the water dispenser
to drip. After connecting the refrigerator to a water source or
replacing the water filter, flush the water system.
Flushing the water dispensing system forces air from the water
line and filter and prepares the water filter for use. Additional
flushing may be required in some households.
NOTE: As air is cleared from the system water may spurt out of
the dispenser.
1. Using a sturdy container, depress and hold the water
dispenser paddle for 5 seconds.
2. Release the dispenser paddle for 5 seconds. Repeat steps 1
and 2 until water begins to flow.
3. Once water begins to flow, continue depressing and releasing
the dispenser pad (5 seconds on, 5 seconds off) until a total of
3 gal. (12 L) has been dispensed.
Calibrate Measured Fill
Household water pressure may affect the accuracy of the
Measured Fill feature. So, for optimum performance of your water
dispenser, you must first calibrate Measured Fill.
IMPORTANT:
Flush the water system before calibrating Measured Fill.
For best results, calibration should be performed when water
is not being used in the house.
1. Place a sturdy measuring cup (1 cup [237 mL] size) on the
dispenser tray centered in front of the ice/water dispenser
paddle.
NOTE: Depending on your model, a measuring cup may be
provided.
2. Press and hold the OPTIONS and LOCK buttons at the same
time for 3 seconds. The words “Back” and “1 Cup” will appear
on the display screen. Also, the Calibrate Measured Fill icon
will illuminate and remain lit while the Measured Fill feature is
being calibrated.
NOTE: You may press ICE/WATER “Back” at any time to exit
calibration mode. The Calibrate Measured Fill icon will
disappear.
3. Press and release the dispenser paddle, as needed, to
dispense water to the 1 cup fill line.
NOTE: If overfilling or spilling occurs, discard the water and
press ICE/WATER “Back” to restart the calibration process.
4. When 1 cup of water has been correctly dispensed into the
measuring cup, press the MEASURED FILL button under the
word “Confirm” to confirm the calibration.
A.Ice/Water dispenser paddle
B.Measuring cup (1 cup)
A
B