WHITE WESTINGHOUSE ICE AND WATER FILTER SYSTEM
SYSTEM SPECIFICATION AND DATA SHEET
APPLICATION GUIDELINES / CONDITIONS OF USE
WATER SUPPLY:
WATER
TEMPERATURE:
WATER
PRESSURE:
Municipal or Well applications
Maximum 100° F. (38° C.) For cold water use only
125 psi maximum Recommended Minimum: 30 psi, as measured at the valve inlet
Timely cartridge replacement is essential for the product to perform as advertised. Please refer to the Use and Care
Manual for general operation and maintenance requirements. Your refrigerator will have one of two types of filter
replacement reminders. One is a simple slide knob on the rear control box that you set to six months after installing a
new filter. The other is an electronic light on the freezer door dispenser that lights up yellow when the filter is almost
ready for replacement and lights up red when the filter must be replaced. The indicator is pressed for approximately
10 seconds to reset after replacing the filter.
Ice & Water Filter System RF-200 should not be used on water that is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system. System may be used on disinfected waters
that may contain filterable cysts.
Performance may vary based on local water conditions and/or pressure. High sediment areas may require more
frequent filter replacement.
Ice & Water Filter System will absorb bad tastes and odors in both ice cubes and drinking water.
SYSTEM SPECIFICATIONS
FLOW RATE:
CAPACITY:
SYSTEM
CONSTRUCTION:
Ice Maker - 3.4 to 4.3 oz (99 - 125 cc) per 7.5 seconds at 60 psi (as measured at valve inlet)
Dispenser - 60 oz per minute (.37 gpm or 1.4 liters per minute) at 60 psi (as measured at valve
inlet)
200 Gallons
Filter Housing Assembly - ABS Plastic
Water Storage Tank - Polypropylene Plastic
Tubing - Polypropylene / Polypropylene Plastic
Filter Media - Extruded Carbon block with Polypropylene prefiltration shells
REPLACEMENT CARTRIDGE INFORMATION
Replacement RC-200 Cartridges are available through your local dealer.
General testwater parameters; pH = 7.5 +/- 0.5 Temp. 20°C +/- 3°C (68°F +/- 5°F) Pressure = 60 psi
Substance
Reduction
Particle Size
Range
(microns)
Average
Influent
Maximum
Effluent
Average
Effluent
Average
%
Reduction
EPA
M.C.L.
Minumun
%
Reduction
Chlorine N/A 1.9 mg/l 0.11 mg/l 0.04 mg/l 97.80% N/A 94.80%
Lead-6.5PH N/A 0.15 mg/l 0.001 mg/l 0.001 mg/l 99.30% 15.0 ug/l 99.20%
Lead-8.5 PH N/A 0.16 mg/l 0.003 mg/l 0.002 mg/l 98.75% 15.0 ug/l 97.90%
Atrazine N/A .0099 mg/l .0006 mg/l .0005 mg/l 94.90% 3.0 ug/l 92.60%
2,4 D N/A 0.32 mg/l 0.04 mg/l 0.018 mg/l 94.20% 70 ug/l 85.20%
Cysts 3 to 4 122500 ppm 20 count/pm 10 count/pm 99.99% N/A 99.98%
Particulates .5 to 1 240000 ppm 880 ppm 410 ppm 99.80% N/A 99.50%
Turbidity 23 - 28 NTU 26 NTU 0.09 NTU 0.07 NTU 99.70% N/A N/A
Automatic Ice and