Wibur Curtis Company D500GT Coffeemaker User Manual


 
TT
TT
T
o Go Into Programmingo Go Into Programming
o Go Into Programmingo Go Into Programming
o Go Into Programming
Turn off (dark display) by pressing
ON/OFFON/OFF
ON/OFFON/OFF
ON/OFF button (yellow). Press and hold
BREWBREW
BREWBREW
BREW button (green) and then press and release
ON/OFFON/OFF
ON/OFFON/OFF
ON/OFF button (yellow).
Continue holding
BREW BREW
BREW BREW
BREW button. Display will read , wait until is displayed Enter the 4-digit access code, the digits 1-4
correspond to the buttons (see illustration below).
The default code set at the factory is 1-2-3-4. Then will be
displayed.
Brew Volume (Factory set to 2.2 Liters)Brew Volume (Factory set to 2.2 Liters)
Brew Volume (Factory set to 2.2 Liters)Brew Volume (Factory set to 2.2 Liters)
Brew Volume (Factory set to 2.2 Liters)
Selecting
Brew by Volume Brew by Volume
Brew by Volume Brew by Volume
Brew by Volume or
Brew by Time Brew by Time
Brew by Time Brew by Time
Brew by Time depends on whether you know your brew time before starting.
From Program Menus press
>>
>>
> display will now show the next feature.
Brew by Brew by
Brew by Brew by
Brew by
VV
VV
V
olumeolume
olumeolume
olume: Press to Select, Display will now show Push START To Begin... Press the
BREWBREW
BREWBREW
BREW button then hot water starts running, when desired
volume is reached press
BREWBREW
BREWBREW
BREW button again to stop the flow. Now the volume has been set. Pressing
>>
>>
> button will display the subsequent menu features.
Next item in the sequence is
Brew by Time.Brew by Time.
Brew by Time.Brew by Time.
Brew by Time. Press to Select to change the brew time. Display will now show the current time. By pressing
<<
<<
< or
>>
>>
> you can
toggle back and forth from minutes to seconds to exit (ex). Change the time or set and exit by pressing .
TT
TT
T
emperaempera
emperaempera
empera
ture (Fture (F
ture (Fture (F
ture (F
actoractor
actoractor
actor
y set to 200y set to 200
y set to 200y set to 200
y set to 200°
F)F)
F)F)
F)
Press to Select. Press
<<
<<
< or
>>
>>
> to move to desired temperature and then to set. Temperature is programmable from 170ºF to 204ºF in 2-degree increments.
Energy Save Mode (Factory set to OFF)Energy Save Mode (Factory set to OFF)
Energy Save Mode (Factory set to OFF)Energy Save Mode (Factory set to OFF)
Energy Save Mode (Factory set to OFF)
Press to Select,
<<
<<
< or
>>
>>
> ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save energy by not heating the tank during periods of non-operation.
Brew Count Odom.Brew Count Odom.
Brew Count Odom.Brew Count Odom.
Brew Count Odom.
Press to display total brew cycles. Press
exex
exex
ex or Reset
Pre-Infusion (Factory set to OFF)Pre-Infusion (Factory set to OFF)
Pre-Infusion (Factory set to OFF)Pre-Infusion (Factory set to OFF)
Pre-Infusion (Factory set to OFF)
Press to Select. Current setting in seconds is displayed
<<
<<
< to decrease or select
>>
>>
> to increase (range from OFF to 10 through 60 seconds), to set.
If Pre-infusion is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock is dissappears from the list of program selections. When Pre-infusion is ON, Pulse Brew
dissappears from the list of program selections.
Brew Count Brew Count
Brew Count Brew Count
Brew Count
TT
TT
T
otalotal
otalotal
otal
Press to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock . . . (Factory set to OFF)Cold Brew Lock . . . (Factory set to OFF)
Cold Brew Lock . . . (Factory set to OFF)Cold Brew Lock . . . (Factory set to OFF)
Cold Brew Lock . . . (Factory set to OFF)
Press to select,
<<
<<
< or
>>
>>
> to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF
is within 30 degrees of set point for the Ready to Brew message, however it will brew at any temperature. This feature will operate after initialization to set temperature after the rear standby toggle switch is
reset to ON.
Master ResetMaster Reset
Master ResetMaster Reset
Master Reset
Press to display
Are Are
Are Are
Are
YY
YY
Y
ou Sure?ou Sure?
ou Sure?ou Sure?
ou Sure?
Then
<<
<<
< for
YY
YY
Y
eses
eses
es,
>>
>>
> for
NoNo
NoNo
No.
Brewer factory defaults are then reset.
Service Call (Phone number Factory set to [800] 995-0417)Service Call (Phone number Factory set to [800] 995-0417)
Service Call (Phone number Factory set to [800] 995-0417)Service Call (Phone number Factory set to [800] 995-0417)
Service Call (Phone number Factory set to [800] 995-0417)
Press to display number and change number or
<<
<<
< to move place and EX to exit when complete This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)Access Code (Factory set to 1-2-3-4)
Access Code (Factory set to 1-2-3-4)Access Code (Factory set to 1-2-3-4)
Access Code (Factory set to 1-2-3-4)
Press to display number and change number, (the number can be change 1 to 4) or
<<
<<
< to move place and
exex
exex
ex to exit when complete.
Banner Name Banner Name
Banner Name Banner Name
Banner Name (Factory set to WILBUR CURTIS)
Press to display letters and change letters or
<<
<<
< to move place and
EXEX
EXEX
EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
P-Maintenance (Factory set to OFF)P-Maintenance (Factory set to OFF)
P-Maintenance (Factory set to OFF)P-Maintenance (Factory set to OFF)
P-Maintenance (Factory set to OFF)
Press to Select, Set gallons brewed to indicate P-Maintenance. Press
<<
<<
< or
>>
>>
> to adjust from Off to 3000 gallons. Press to exit.
Beeper On/Off (Factory set to ON)Beeper On/Off (Factory set to ON)
Beeper On/Off (Factory set to ON)Beeper On/Off (Factory set to ON)
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either
<<
<<
< or
>>
>>
> toggles between on and off. to set.
PROGRAM MENUS
2
During actual brew cycle a
2-minute drip mode is added to
the brew time. The programmed
water level compensates for back
to back brewing in Delta 3 to allow
for an increase of water volume.
YY
YY
Y
our Curtis our Curtis
our Curtis our Curtis
our Curtis
ADS System is FADS System is F
ADS System is FADS System is F
ADS System is F
actoractor
actoractor
actor
y Pre-Set for Optimum Py Pre-Set for Optimum P
y Pre-Set for Optimum Py Pre-Set for Optimum P
y Pre-Set for Optimum P
erformance.erformance.
erformance.erformance.
erformance.
After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller.
The control displays . Press ON/OFF button and the screen will display . After three seconds,
is displayed.
Water will fill the tank (approximately 2-3 minutes depending on water flow rate). When the proper level is reached
will appear on the
screen. It takes approximately 20 minutes to reach setpoint temperature of 200°F.
Control will display when temperature reaches the setpoint (200°F). Unit is now ready to brew.
<Airpot Brewer>
WILBUR CURTIS
WILBUR CURTIS
WILBUR CURTIS
FILLING
WILBUR CURTIS
HEATING
ENTER CODE
– – – –
PROGRAM MENUS
< SELECT >
WILBUR CURTIS
READY TO BREW
ENTERING PROGRAM
MODE
D500 GT
Quick Start
1 2 3
4
All programming selections are performed with the three center buttons.
The symbols below the buttons are:
Scroll LEFT
SELECTION or ENTER to save new parameter
Scroll RIGHT