Windster RA.3030/3036 Ventilation Hood User Manual


 
J. Making the Electrical Connection
1. Turn the six nuts at the front/back of bottom board. ( Fig.13)
2. Remove screws on wiring case.
fish out wires through the
knockout. (Fig.13)
screw
Fig.!
3. Mark the electrical connection by fastening all wires to the existing
wall wiring according to the their colors. (Black to Black, White to
White. Green to Ground)
4. After connection is done, reinstall wiring case cover and bottom
board.
5. Slide plastic collection cups onto the back metal mounting.
6. Turn on power and check operation of fan and light.
-11-