Wolf FS-4J-0-24M Range User Manual


 
NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39111 (9/05)
Commander Series
24" Wide Heavy-Duty Modular Gas Ranges
INSTALLATION REQUIREMENTS:
1. In order for this equipment to operate as designed, an adequate
gas supply (volume and pressure) must be delivered to the
installation. Natural gas 5.0" W.C., propane gas 10.0" W.C.
2. A properly sized gas pressure regulator must be installed with
this equipment.
3. An adequate ventilation system is required for commercial cook-
ing equipment. Information may be obtained by writing to the
National Fire Protection Association, 1 Batterymarch Park,
Quincy, MA 02269, www.NFPA.org. When writing, refer to NFPA
No. 96.
4. These units are manufactured for installation in accordance with
ANSZ223.1A (latest edition), National Fuel Gas Code. Copies
may be obtained from The American Gas Association, 400 N
Capitol St. NW, Washington, DC 20001, www.AGA.org.
5. Clearances: Combustible Non-combustible
Rear 2" 0"
Sides 20" 2"
ACCESSORIES — ALL MODELS:
26
1
2" or 37
3
4" high stainless steel back riser. (Common back
risers available up to 96" wide.)
26
1
2" high single deck high shelf. (Common high shelves avail-
able up to 96" wide.)
26
1
2" high single deck flo-thru high shelf. (Common high
shelves available up to 96" wide.)
37
3
4" high double deck high shelf. (Common high shelves avail-
able up to 96" wide.)
Gas pressure regulator (specify size and type of gas).
Flexible gas hose with quick disconnect and restraining device.
Consult price book for available sizes.
MODEL BTU/HR. WORKING APPROX. SHP. WT.
NO. INPUT WIDTH DEPTH HEIGHT LBS./KG
FS-4J-0-24-M 120,000 280/126
FS-2J-0-2HHT-24-M 95,000
24" 38" 36"
300/135
FS-0-0-FT-24-M 60,000 360/162
FS-0-0-2HT-24-M 70,000 340/153
FS-4J-0-24-M FS-2J-0-2HHT-24-M
FS-0-0-FT-24-M FS-0-0-2HT-24-M