INSTALLATION INSTRUCTIONS
LOCATION REQUIREMENTS
Illustrations on the following pages provide the
overall dimensions, countertop cut-out and
installation specifications for Wolf gas
cooktops. Maintain the following minimum
installation dimensions:
Minimum horizontal clearance from the
sides and back of the cooktop cut-out to
adjacent vertical combustible construction,
extending a minimum of 457 mm above the
countertop, is as follows: 178 mm from side
edges of cut-out for the 381 mm cooktop;
229 mm from side edges of cut-out for the
762 mm and 914 mm cooktops; 64 mm
from rear edge of cut-out.
Minimum vertical distance between the
countertop and combustible materials
above the cooktop must be 762 mm.
Maximum 330 mm depth of overhead side
cabinets directly above and within side
clearance.
IMPORTANT NOTE:
When installing a ventila-
tion hood, refer to the specific requirements
of the hood for the minimum dimension to
countertop.
BEFORE YOU START
Check the location where the cooktop will
be installed. The location should be away
from strong draft areas, such as windows,
doors and strong heating vents or fans. Do
not obstruct flow of combustion and
ventilation air.
This appliance is not connected to a
combustion products evacuation device. It
shall be installed and connected in accor-
dance with current installation regulations.
Particular attention shall be given to the
relevant requirements regarding ventilation.
SITE PREPARATION
COUNTERTOP CUT-OUT DIMENSIONS
IMPORTANT NOTE:
Countertop opening
dimensions shown on the following pages
must be used. The dimensions shown provide
for required clearances.
These cooktops are designed to fit a standard
610 mm deep base cabinet with a 635 mm
deep countertop. Before making the counter-
top cut-out, verify that the cooktop will clear
the side walls of the base cabinet below. There
should be at least 140 mm clearance between
the countertop and any combustible surface
directly below the unit.
IMPORTANT NOTE:
Do not seal the cooktop
to the countertop. It must be removed if
service is necessary.
Failure to locate the cooktop without the
proper clearances will result in a fire
hazard.
This cooktop is intended for indoor use.