Wolf ICBCT30I Cooktop User Manual


 
15
INSTALLATION I N ST RU C T IO N S
F
R A ME L E S S I N STAL LATI ON
Unframed induction cooktop Models
ICBCT30IU and ICBCT36IU can be installed as a
frameless application, with the glass mounted
on top of the countertop surface. For counter-
top cut-out dimensions, refer to the Installation
Specifications illustration on page 12 for Model
ICBCT30IU and page 13 for Model ICBCT36IU.
UNFRAMED I N S TA L L AT I O NS
F
L U SH M OU N T I N S TA L LATI ON
OPTION 2:
For this flush mount installation,
the countertop cut-out will be the same size as
the outer edge of the glass top. It is recom-
mended that cooktop itself be used as the
template for the cut-out. Turn the cooktop over
and mark the opening using the glass top as a
template.
It will be necessary to attach L-shaped brackets
or cleats to the inner perimeter of the cut-out
to support the cooktop. The top edge of the
bracket can be no wider than 22 mm and will
be attached 8 mm below the surface of the
countertop. Refer to the illustration below.
Attachment of the brackets is up to the
installer's discretion, wherever enough coun-
tertop material is present.
For additional support in the cut-out area,
adhere scrap countertop material to the
bottom side of the countertop. Consult your
countertop supplier for the proper methods of
attachment.
22 mm
8 mm
L-Shaped
Brackets
Flush mount installation brackets