Wolf M15/S Cooktop User Manual


 
INSTALLATION NOTES
Natural gas installations above 10,250' and
LP gas installations above 8,600' require the
high altitude conversion kit.
Complete installation specifications can be
found on our website, wolfappliance.com.
S
hown with wok grate.
Unit dimensions may vary by ±
1
/8".
SPECIFICATIONS
Exterior Finish Stainless Steel
Overall Width 15"
Overall Height 5"
Overall Depth 21"
Burner Rating 22,000 Btu
Minimum Cabinet Depth 22
3
/4"
Minimum Height Clearance* 5"
Countertop Cut-Out Width 14"
Countertop Cut-Out Depth 19
1
/4"
Electrical Requirements 120 V AC, 60 Hz
15 amp circuit
Power Cord 6' cord with grounded plug
Gas Rating 22,000 Btu
Shipping Weight 30 lbs
*A minimum height clearance of 5
1
/2" is required
between countertop and any combustible surface
directly below the cooktop.
INSTALLATION SPECIFICATIONS
OVERALL DIMENSIONS
Gas Multi-Function Cooktop
Dimensions in parentheses are in
millimeters unless otherwise specified.
1
/2"(13)
SIDES
1"(
25)
FRONT/ BACK
5"(127)
21"(
533)
15"
(381)
36"(914)
FLOORTO
COUNTERTOP
30"(762) min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
SEE COUNTERTOP
CUT-OUT BELOW
14"(356)
CUT-OUT
WIDTH
COUNTERTOP CUT-OUT
FRONT
19
1
/4"(489)
CUT-OUT
DEPTH
2
1
/2"(64) min
7"(178)TO
COMBUSTIBLE*
7"(178)TO
COMBUSTIBLE*
SIDE
CABINET
13"(330)
max
*Minimum clearance from cooktop cut-out to combustible materials up to 18"(457) above countertop.
NOTE: Application shown allows for installation of two 15"
(381) modules side by side.
E
15"(381)
15"
(381)
4"
(
102
)
18"(457) min
5"
(127)
LOCATION OF GAS
AND ELECTRICAL
EXTENDS ON FLOOR
G
2
1
/2"
(64)*
Countertop Cut-Out Dimensions
©Wolf Appliance, Inc. all rights reserved. Features and specifications are subject to change at any time without notice. 1/10