Wolf WKGC 126622 Convection Oven User Manual


 
FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F32700 (February 2006) Page 8 of 64
TEMPERATURE PROBE
(WKGD/WKGDX)
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Remove the right side panel as outlined under
COVERS AND PANELS.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2. Disconnect the probe leads from the temperature
control.
3. Remove the racks and right rack support.
4. Remove probe clips from probe.
5. Push the probe through the opening in cavity side
wall and into the control panel area.
NOTE: The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
6. Reverse the procedure to install the replacement
probe.
7. Adjust the temperature control as outlined under
SOLID STATE TEMPERATURE CONTROL
CALIBRATION (WKGD/WKGDX) in SERVICE
PROCEDURES AND ADJUSTMENTS.
GAS BURNER
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1. Remove the lower front cover as outlined under
COVERS AND PANELS.
2. Disconnect the ignition cable and the flame sense
lead wire.
3. Remove the bolts securing the gas manifold and
place manifold aside.
4. Remove the screws securing the burner cover
then lift out.
5. Grasp the burner and lift out.