Wolf Appliance Company 1200 Cooktop User Manual


 
All information is subject to change. Refer to www.wolfappliance.com for current information
CHOOSING VENTILATION
Dual Fuel Ranges, Sealed Burner Rangetops (SRT), Gas Ranges, Gas Range Top (GRT)
30” and 36” Appliances
BLOWER AND RECOMMENDED MINIMUM CFMs
PRODUCT HOOD RECOMMENDATION Internal In-Line External/Remote
30” Dual Fuel, 30” Gas Range, 30” SRT
30” PRO Low-Profile Wall Hood 500 600 600
36” PRO Low-Profile Wall Hood 500 600 600
30” PRO Deep Wall Hood (24” or 27”) 600 600 600
36” PRO Deep Wall Hood (24” or 27”) 600 1100 900
36” PRO Wall Chimney Hood 600 1100 900
42” PRO Wall Chimney Hood 600 1100 900
34” PRO Hood Liner 1200 1100 900
40” PRO Hood Liner 1200 1100 900
36” PRO Island Hood 1200 1100 900
42” PRO Island Hood 1200 1100 900
36” Dual Fuel, 36” Gas Range, 36” SRT, 36” GRT
36” PRO Low-Profile Wall Hood 500 600 600
42” PRO Low-Profile Wall Hood n/a 600 600
36” PRO Deep Wall Hood (24” or 27”) 600 1100 900
42” PRO Deep Wall Hood (24” or 27”) 600 1100 900
36” PRO Wall Chimney Hood 600 1100 900
42” PRO Wall Chimney Hood 600 1100 900
34” PRO Hood Liner 1200 1100 900
40” PRO Hood Liner 1200 1100 900
36” PRO Island Hood 1200 1100 900
42” PRO Island Hood 1200 1100 900