Wolf Appliance Company DF486G Range User Manual


 
Planning Information
48" (1219) Dual Fuel Ranges
MODELS DF486C, DF486G, DF484CG, DF484DG AND DF484F
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
INSTALLATION NOTES
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf dual
fuel range to avoid any fires or damage to
adjacent cabinetry or kitchen equipment. Be
sure to follow minimum clearances established
in the finished rough opening dimensions as
shown in the illustration on page 4.
IMPORTANT NOTE: A minimum 10" (254) riser
is required for all 48" (1219) dual fuel range
models installed against a combustible surface.
A Wolf Pro ventilation hood or hood liner is
recommended. When installing a ventilation
hood, refer to the specific requirements of the
hood for the minimum dimension to countertop.
Also refer to the ventilation recommendation
charts in the Pro ventilation section of our
website, wolfappliance.com.
The 48" (1219) dual fuel range requires a
240/208 V AC, 60 Hz, 50 amp fused electrical
supply to operate the electrical portions of the
range. Locate electrical within the shaded area
shown in the illustration on page 4.
Wolf dual fuel ranges are designed with a
terminal block on the rear of the range. The
terminal block allows for a 3-wire or 4-wire
installation. For a 4-wire installation, the ground
strap from the unit to the terminal block must
be cut. Two concentric knockouts on the base
of the unit are provided to allow a certified elec-
trical contractor to wire the range directly to the
electrical supply. The terminal block will also
accept an appliance cord that is sized correctly
for the range’s voltage and amperage.
Wolf dual fuel ranges are designed to operate
on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure
to the regulator should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa).
Wolf recommends the use of a
1
/2" (13) I.D.
commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be
3
/4" (19) minimum I.D. pipe.
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range in
an accessible location.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing
your services.
Wolf dual fuel ranges using natural gas
function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas and LP gas
installations from 8,000' (2438 m) to 11,000'
(3353 m) need the high altitude kit. Contact
your Wolf dealer for details. To obtain local
dealer information, visit the Showroom Locator
section of our website, wolfappliance.com.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.