Wolf Appliance Company IM15 Cooktop User Manual


 
Multi-Function Cooktop Specifications 4
1
/2"(13)
SIDES
1"(
25)
FRONT/ BACK
5"(127)
21"(
533)
15"
(381)
Overall Dimensions
MULTI-FUNCTION COOKTOP
Installation Specifications
IMPORTANT NOTE: Installation of the Wolf gas multi-
function cooktop must meet minimum clearance require-
ments shown in the installation specifications illustration
on the following page.
The Wolf multi-function cooktop is intended for indoor
use. An adequate supply of fresh air is required to assure
proper combustion and ventilation. It is designed to fit a
standard 24"
(610) deep base cabinet with 25" (635) deep
countertop. Before making the countertop cut-out, verify
that the module will clear the side walls of the base
cabinet.
There should be at least 5
1
/2" (140) clearance between the
countertop and any combustible surface directly below
the multi-function cooktop.
If the multi-function cooktop is not installed above an
oven, the gas service may be supplied through the floor.
When an oven is installed below the cooktop, unless you
are using cabinets deeper than 24"
(610), it is recom-
mended that the electrical supply be placed in the base
cabinet to the right of the oven. Refer to the illustration
on the following page for specifics on placement of the
electrical and gas supply.
It is recommended that you use a Wolf cooktop ventilation
hood, downdraft, pro hood or hood liner with the multi-
function cooktop. Refer to the Wolf design guide.
Failure to locate the multi-function cooktop without the
proper clearances will result in a fire hazard.