Wolf Appliance Company IM15 Cooktop User Manual


 
Multi-Function Cooktop Specifications 7
wolfappliance.com/specs
Gas Supply Requirements
GAS MANIFOLD PRESSURE
Natural Gas: Standard orifices are set for 5" (12.5 mb)
WC (water column).
LP Gas: Standard orifices are set for 10"
(25 mb) WC.
Gas Supply Pressure: The maximum gas supply
pressure to the regulator should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa) for natural and LP gas.
The minimum line pressure is 7"
(17.5 mb) WC for
natural gas and 11"
(27.4 mb) WC for LP gas.
Gas Pressure Regulator: To control and maintain a
uniform gas pressure in the gas manifold, the unit must
be used with a gas pressure regulator. The burner
orifices, etc. are sized for the gas pressure delivered by
the supplied regulator. Do not remove the regulator.
The maximum gas supply pressure to the regulator
should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa).