Wolf Appliance Company IS15/S Range User Manual


 
Steamer Module Operation
INITIAL START-UP
Before using for the rst time, clean your steamer module
thoroughly with hot water and a mild detergent. Rinse and
dry with a soft cloth. This removes any residual oil and
grease left on the surface from the manufacturing process.
Refer to care recommendations on page 16.
When the steamer module is powered up for the rst time
it will default to lock mode. To unlock the control panel,
touch and hold the key symbol for 3 seconds.
IMPORTANT NOTE: A small amount of smoke and odor
may be noticed during the initial break-in period.
WATER LEVEL
CAUTION
Water must be added to the steamer basin before
operating the steamer module.
Before operating, ll the steamer basin with water until
level with the minimum water level line. Refer to the
illustration below.
Modes of Operation
LOCK MODE
In lock mode, all touch pad operations on the control panel
are disabled and the heating element is deenergized. A
steady glowing light within the key symbol indicates that
the module is locked. Refer to the illustration below.
t To lock the control panel, touch and hold the key
symbol for 3 seconds. Three chimes will sound and the
light within the key symbol will illuminate. The module is
now in lock mode.
t To unlock the control panel, touch and hold the key
symbol for 3 seconds. Two chimes will sound and the
light within the key symbol will go out. The module is
now in idle mode.
IMPORTANT NOTE: When the module is powered up for
the rst time or if there has been a power outage, the
module will default to lock mode.
IDLE MODE
After unlocking the control panel as described in lock
mode, the module enters the idle mode of operation. All
touch pad operations on the control panel are enabled.
Steamer Module Operation 8
Temperature
LED display
Lock key
touch pad
Power bar
indicator
DRAIN
touch pad
Temperature
adjustment
OFF ON
touch pad
Timer LED
display
CLEAR
touch pad
Control panel.
Water level.
MINIMUM
WATER LEVEL