Wolf Appliance Company MWC24 Microwave Oven User Manual


 
Planning Information
Convection Microwave Oven
MODEL MWC24
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
INSTALLATION NOTES
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
The Wolf convection microwave oven can be
used freestanding or with an optional trim kit.
30" (762) and 36" (914) L Series trim kits and
27" (686) and 30" (762) E Series trim kits are
available. These trim kits match Wolf L Series
and E Series built-in ovens. With a trim kit the
microwave can be built-in in combination with
an L Series or E Series single oven of corre-
sponding style and width.
IMPORTANT NOTE: While the look of the 30"
(762) L Series and E Series microwave trim kits
will differ, the rough opening dimensions are
the same.
IMPORTANT NOTE: In all instances where the
microwave oven is built in, you must use one of
the trim kits to ensure proper ventilation.
The Wolf convection microwave oven with
trim kit will overlap stiles and rails. Trim
overlaps for the 30" (762) L Series and E Series
trim kits are
13
/16" (21) on the bottom,
5
/16" (8)
on the top and 1
3
/16" (30) on each side. Trim
overlaps for the 27" (686) E Series trim kit are
13
/16" (21) on the top and bottom, and
5
/8" (16)
on each side.
The base platform for the microwave oven
must be able to support 125 lbs (57 kg).
At installation, wood cleats (not included)
must be added to the microwave opening
for the trim.
Refer to the installation instructions provided
with the microwave trim kit for detailed specifi-
cations. These instructions can also be found
on the Wolf website at wolfappliance.com.
When using the convection microwave oven
as a freestanding unit, allow 2" (51) of airflow
space on top, rear and both sides. A minimum
20
1
/8" (511) cabinet depth is required.
The Wolf convection microwave oven
requires a separate, grounded 110/120 V AC,
60 Hz power supply. The service should have
its own 15 amp circuit breaker and a grounded
3-prong receptacle should be located within the
reach of the 3
1
/2' (1.1 m) power cord. Locate
electrical within the shaded area shown in the
illustrations on pages 4–6.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
The Wolf convection microwave oven with
trim may be installed in combination with a
built-in single oven and warming drawer. Be
sure that the trim matches the series of oven
and warming drawer front you are using in your
design. Refer to pages 8–10 for specifications.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.